  agency listings CO1224 carbon monoxide detector system sensors CO1224 provides early warning when its electrochemical sensing technology accurately measures carbon monoxide levels in the air. features full compliance with ul 2075 a code required trouble relay wiring supervision with sems terminals a six-year end-of-life timer 12/24 vdc a current draw of 20ma in standby and 40ma in alarm versatile mounting for wall and ceiling electrochemical sensing technology ? ? ? ? ? ? ? ? carbon monoxide is an odorless, colorless, tasteless and highly toxic gas that is produced when fuels, such as wood, gasoline, charcoal and oil, are burned with insufcient air. the majority of residential and commercial fatalities caused from these fuels come from heating systems, power tools and charcoal grills. if carbon monoxide is detected, the CO1224 will alert residents by sounding and fashing a temp-4 signal alarm. protection is guaranteed 24/7 by a central station, regardless of whether residents are away from home, sleeping or already sufering from the efects of co. the CO1224 is specifcally designed for system operation. this means the detector is fully listed to ul 2075, ofering a code required trouble relay, which sends a sensor failure or end-of-life signal to the control panel and the central station, as well as sems-type terminal philips-head screws, which provide a quicker and more positive wiring connection and code required wiring supervision. also, the CO1224 ofers a low current draw, allowing more detectors to be connected to the panel without having to purchase a more expensive panel or an extra power supply. because the CO1224 is a 12/24 vdc detector, it will operate on most industry security or fre alarm control panels. 2075 5276-1653:194 454-06-e
3825 ohio avenue ? st. charles, il 60174 phone: 800-sensor2 ? fax: 630-377-6495 ?2007 system sensor. product specifcations subject to change without notice. visit systemsensor.com for current product information, including the latest version of this data sheet. a05-0402-002 ? 3/07 ? #1772 ordering information part no. description CO1224 12/24 volt, 4-wire system-monitored carbon monoxide detector specifications architectural/engineering specifcations carbon monoxide detector shall be a system sensor model number CO1224, listed to underwriters laboratories ul 2075 for gas and vapor detectors and sensors. the detector shall be equipped with a sounder and a trouble relay. the detectors base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. wiring connections shall be made by means of sems screws. the detector shall provide dual color led indication, which blinks to indicate normal standby, alarm, or end-of-life. when the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. when the detector gives a trouble or end-of-life signal, the detector shall be replaced. electrical specifcations operating voltage 12/24 vdc audible signal 85 db in alarm standby current 20 ma alarm current 40 ma (75 ma test) alarm contact ratings 0.5 a @ 30 vdc trouble contact ratings 0.5 a @ 30 vdc physical specifcations size length: 5.1?, width: 3.3?, height: 1.3? approximate weight 7 oz operating temperature range 0 C 40 c (32 C 104 f) operating humidity range 22 C 90% rh input terminals 14 C 22 awg mounting single-gang back box; surface mount to wall or ceiling operation modes operation mode green led red led sounder normal (standby) blink 1 per minute alarm blink in temp 4 pattern sound in temp 4 pattern hush feature: pushing the test/hush button will silence the sounder for 5 minutes. trouble feature: when the detector is in a trouble condition, it will send a trouble signal to the panel. end-of-life timer: after the sensor inside the detector has reached the end of its useful life, a trouble signal will be sent to the panel. this will indicate that it is time to replace the detector. an electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product.


▲Up To Search▲   

 
Price & Availability of CO1224

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X